• 60KW DC fast charging station
  • 60KW DC fast charging station
  • 60KW DC fast charging station
  • 60KW DC fast charging station
  • 60KW DC fast charging station
60KW DC fast charging station
discuss personally
Model
WZ05-60kW-3CEJ-30INGYNN
WZ05-60kW-2EJ-30INGYNN
WZ05-60kW-2EU-30INGYNN
WZ05-60kW-2E-30INGYNN
WZ05-60kW-2C-30INGYNN
Basic info
Brand RW Energy
Model NO. 60KW DC fast charging station
Rated Output Rating 60kW
Output Voltage DC 200-1000V
Max Output Current 200A
Power Conversion Efficiency ≥95%
Connector Options GBT+CCS2+CHAdeMO
Cable Length 5m
Input Voltage 380V
Series DC EV Chargers
Product Detail

Description:

This DC fast charging station supports mainstream charging standards including CCS1, CCS2, CHAdeMO, GBT, and Tesla, allowing flexible customization and combination to achieve full compatibility with all electric vehicle brands. Whether it's CCS fast-charging models in the European and American markets, Japanese CHAdeMO protocol vehicles, Chinese GBT standard vehicles, or Tesla's entire lineup, all can be charged instantly upon plugging in.

Key Features:

  • Multi-Standard Compatibility: Resolves charging interface differences across brands and regions in one go, eliminating the need for additional adapters.

  • Flexible Customization: Supports free combination of single or multiple standard modules to suit diverse scenarios such as commercial operations, highway rest areas, and community charging stations.

  • High-Efficiency Fast Charging: With a maximum output power of 350kW, it can charge a vehicle from 10% to 80% in just 30 minutes.

  • Intelligent Management: Integrated smart monitoring system for real-time tracking of charging status, power distribution, and device health, supporting remote operation and maintenance.

  • Safe & Reliable: Equipped with overvoltage/overcurrent protection, leakage monitoring, and temperature control systems to ensure safe and stable charging throughout the process.

Technical Parameters:

image.png

image.png

image.png

Is the DC fast charging station a specific implementation of leakage protection?

Specific implementation of leakage protection:

  •  Hardware level:Residual current device: Install a residual current device inside the charging station. When the leakage current detected exceeds the set threshold, the power supply is automatically cut off.

  • Current transformer: Install a current transformer inside the charging cable or charger to monitor current changes in real time. Once abnormal current is detected, the protection action is triggered.

  • Ground fault protection: Integrate a GFCI inside the charging station to detect ground faults and cut off the power supply.

Software level:

  • Fault detection algorithm: Monitor the change of current through software algorithms. When abnormal current is detected, the system will issue an alarm and cut off the power supply.

  • Real-time monitoring: Monitor parameters such as current and voltage during the charging process in real time. Once an abnormality is found, protection measures are taken.


Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the